Selecting the correct electrical termination is not a formality. This is a decision on which the safety of the line, the service life of the cable and the stability of the entire distribution network depend. We regularly see how, in 10-35 kV projects, replacing one type of coupling with another solves the problem of repeated flashovers during lightning surges. Or how an incorrectly selected tip causes local overheating after only 8 months of operation in conditions of high humidity and temperature cycles. All this is not a theory. This is data from our tests in the laboratory up to 1000 kV and feedback from 147 energy supply companies in the CIS countries and the Middle East.
Electrical terminations are not just “plugs” at the end of a cable. These are engineering solutions that compensate for field strength, seal the joint, provide mechanical fixation and heat removal. An incorrect choice leads to partial discharges, corrosion of current-carrying conductors, destruction of insulation and emergency shutdown. Below are five main types, grouped by installation principle and application.
One of the most frequently asked questions is: “Can heat shrink be replaced with cold shrink?” The answer is yes, but only after recalculating the electric field and checking compatibility with the cable sheath. For example, for cables with aluminum armor, we recommend only specially adapted versions of cold-shrinkable sleeves - standard samples do not provide sufficient protection against stray currents.
Clients often underestimate the role of climate control solutions. For areas with sharp temperature changes (for example, Kazakhstan, Siberia, Armenia), we supply terminations with an increased elasticity of the silicone shell and a reinforced sealing system. A conventional coupling here can lose its tightness within a year, but ours has been working without failure for more than 12 years.
Shijiazhuang Hist Electric Co., Ltd. does not just produce 5 types of electrical terminations. We design them for specific conditions: type of soil, level of air pollution, frequency of thunderstorms, mechanical loads during installation. Each batch undergoes incoming inspection of raw materials, intermediate checks at all stages of assembly and acceptance tests in our own laboratory. This allows us to guarantee stable quality regardless of the order volume - from 10 pieces to 5000.
If you choose termination for a new object, start by calculating the electric field in the area of the cable end. If this is an upgrade, check the compatibility of the new solution with the old cable and fittings. And always consider who will install it: heat shrink requires trained personnel and a heat gun, and cold shrink requires strict adherence to instructions and control of cleanliness.
The correct choice of 5 types of electrical terminations is not a compromise between cost and reliability. This is an accurate engineering calculation that takes into account the physics of processes, operating features and real installation limitations. This is how we work with every order - from the initial technical request to warranty support throughout the entire service life.