China, Hebei province, Shijiazhuang, st. Minxin donglu, no. 6
Lightning rod 6 kV
Lightning rod 6 kV

Lightning rod 6 kV

Main components: Using zinc oxide valve plates, with non-linear current-voltage characteristics and response time ≤ 25ns. Shell material: silicone rubber or ceramic material, strong weather resistance (-40℃~85℃), suitable for outdoor environments with high humidity and salt fog.

Plug-in switch-GW13

Plug-in switch-GW13

GW13 series is an outdoor high voltage AC isolation switch designed specifically for 50Hz AC power systems. Mainly used to open and close circuits under no-load conditions to achieve electrical isolation or connect the neutral point of a transformer

Plug-in switch-GN30-12D

Plug-in switch-GN30-12D

GN30-12D is a special model of GN30-12: built-in grounding blade, increasing the safety of the grounding system. Supports manual control, control the movement of the blade by turning the handle.

Plug-in switch-GN30-12

Plug-in switch-GN30-12

The disconnector type GN30-12 is a rotating contact blade for indoor high-voltage switchgear, suitable for power systems with 50 Hz alternating current and 12 kV rated voltage. It is mainly used to open and close circuits under no-load conditions to achieve electrical isolation. Its compact design is suitable for installation in high-voltage switchgears, improving distribution system space utilization

Plug-in switch-GN19-12

Plug-in switch-GN19-12

The GN19-12 type disconnect switch is an indoor high-voltage switching device widely used in power systems with 50 Hz alternating current and 12 kV rated voltage. Mainly used to open and close circuits under no-load conditions to achieve reliable insulation between electrical equipment and power supply. It is divided into regular type (GN19-12) and wall type (GN19-12C), and supports three-phase parallel installation or wall installation in special scenarios.

disconnector-HRWK-0.5400~800

disconnector-HRWK-0.5400~800

HRWK series is a low voltage fused isolation switch designed for 50Hz AC distribution systems with rated voltage of 0.5kV and below, with circuit isolation and short circuit protection functions.

disconnector-HJDW6-0.5630~2000

disconnector-HJDW6-0.5630~2000

HJDW6 series is a low voltage fused isolation switch designed specifically for 50Hz AC distribution lines with rated voltages of 500V and below. Mainly used for short circuit, overload, open circuit and short circuit protection under no-load conditions on the low voltage side of transformers

Disconnector-(H)GW5-126kV(138kV)

Disconnector-(H)GW5-126kV(138kV)

GW5 Isolation Switch 126-138KV Isolation Switch (also known as Disconnector) Rated Voltage: 126KV, Suitable for Three-Phase AC 50Hz High Voltage Transmission System, Support Outdoor Operation in Difficult Environment

Disconnector-(H)GW5-40.5kV

Disconnector-(H)GW5-40.5kV

GW5 Isolation Switch 40.5 kV Isolation Switch (also known as disconnector) Double column horizontal rotating, consists of insulated posts, conductive blades, base and control mechanism. The blades move horizontally at a constant speed when opening and closing, with strong ice breaking ability. The insulation support is a rod structure that prevents contamination.

Disconnector-(H)GW4-220kV

Disconnector-(H)GW4-220kV

GW4-220 isolation switch is an open AC isolation switch designed specifically for 220kV high voltage power systems, mainly used for circuit switching and electrical isolation of equipment under no-load conditions.

Disconnector-(H)GW4-126kV(138kV)

Disconnector-(H)GW4-126kV(138kV)

GW4 Isolation Switch 126-138 kV Isolation Switch (also known as a disconnector) Used for line isolation, equipment maintenance, or power system switching during no-load conditions, cannot disconnect loads or fault currents and must be used in conjunction with circuit breakers.

Disconnector-(H)GW4-72.5kV

Disconnector-(H)GW4-72.5kV

GW4 Isolation Switch 72.5kV Isolation switch (also known as disconnector) 72.5kV, suitable for high voltage 50/60Hz three-phase AC transmission system. Insulation characteristics: lightning impulse withstand voltage 185 kV (to ground), power frequency withstand voltage 100 kV (to ground), higher value of failure withstand voltage, ensuring the reliability of electrical insulation after tripping.

<<<123456>>> 3 / 7

Products

Shijiazhuang Hist Electric Co.,Ltd was founded in 2004, we are one of the professional cable accessories manufacturers in China. With strong technical strength in electrical engineering field, the company is capable of providing comprehensive construction solutions and technical support for cable accessories to customers in different regions and types in various complex construction environments.

Home
Products
About Us
Contacts

Пожалуйста, оставьте нам сообщение

Privacy Policy

Thank you for using this site (“we”, “us” or “our”). We respect your rights and interests in personal information, comply with the principles of legality, legitimacy, necessity and integrity, and protect your information security. This policy describes how we process your personal information.

1. Collection of information
Information you provide voluntarily, such as name, mobile number, email address, etc., is completed during registration. Information such as device model, browser type, access logs, IP address, etc. is automatically collected to optimize service and security.

2. Use of information
provide, maintain and optimize website services;
account verification, security protection and fraud prevention;
Send necessary information such as service notifications and policy updates;
Comply with laws, regulations and applicable regulatory requirements.

3. Protection and exchange of information
We use security measures such as encryption and access controls to protect your information and only store it for the minimum period necessary to complete the task.
Do not sell or rent personal information to third parties without your consent; Share only if:
Get your explicit permission;
third parties entrusted to provide services (subject to confidentiality obligations);
Respond to legal requests or protect legitimate interests.

4. Your rights
You have the right to access, correct and supplement your personal information, and you can also apply to cancel your account (after cancellation, the information will be deleted or anonymized according to the rules). To exercise your rights, you may contact us using the contact details provided below.

5. Policy Updates
Any changes to this policy will be notified by posting on the site. Your continued use of the services means your acceptance of the amended rules.